CounterSample Constructeurs

Définition

Initialise une nouvelle instance de la CounterSample structure.

Surcharges

Nom Description
CounterSample(Int64, Int64, Int64, Int64, Int64, Int64, PerformanceCounterType)

Initialise une nouvelle instance de la CounterSample structure et définit la CounterTimeStamp propriété sur 0 (zéro).

CounterSample(Int64, Int64, Int64, Int64, Int64, Int64, PerformanceCounterType, Int64)

Initialise une nouvelle instance de la CounterSample structure et définit la CounterTimeStamp propriété sur la valeur passée.

CounterSample(Int64, Int64, Int64, Int64, Int64, Int64, PerformanceCounterType)

Source:
CounterSample.cs
Source:
CounterSample.cs
Source:
CounterSample.cs
Source:
CounterSample.cs
Source:
CounterSample.cs
Source:
CounterSample.cs
Source:
CounterSample.cs
Source:
CounterSample.cs

Initialise une nouvelle instance de la CounterSample structure et définit la CounterTimeStamp propriété sur 0 (zéro).

public:
 CounterSample(long rawValue, long baseValue, long counterFrequency, long systemFrequency, long timeStamp, long timeStamp100nSec, System::Diagnostics::PerformanceCounterType counterType);
public CounterSample(long rawValue, long baseValue, long counterFrequency, long systemFrequency, long timeStamp, long timeStamp100nSec, System.Diagnostics.PerformanceCounterType counterType);
new System.Diagnostics.CounterSample : int64 * int64 * int64 * int64 * int64 * int64 * System.Diagnostics.PerformanceCounterType -> System.Diagnostics.CounterSample
Public Sub New (rawValue As Long, baseValue As Long, counterFrequency As Long, systemFrequency As Long, timeStamp As Long, timeStamp100nSec As Long, counterType As PerformanceCounterType)

Paramètres

rawValue
Int64

Valeur numérique associée à l’exemple de compteur de performances.

baseValue
Int64

Valeur brute de base facultative pour le compteur, à utiliser uniquement si l’exemple est basé sur plusieurs compteurs.

counterFrequency
Int64

Fréquence à laquelle le compteur est lu.

systemFrequency
Int64

Fréquence à laquelle le système lit à partir du compteur.

timeStamp
Int64

Horodatage brut.

timeStamp100nSec
Int64

Horodatage brut et haute fidélité.

counterType
PerformanceCounterType

Objet PerformanceCounterType qui indique le type du compteur pour lequel cet exemple est un instantané.

Remarques

Utilisez ce constructeur pour prendre un échantillon initial du compteur de performances. Le Moniteur système fournit automatiquement des valeurs pour ces paramètres lorsque vous appelez la NextSample méthode pour la première fois.

S’applique à

CounterSample(Int64, Int64, Int64, Int64, Int64, Int64, PerformanceCounterType, Int64)

Source:
CounterSample.cs
Source:
CounterSample.cs
Source:
CounterSample.cs
Source:
CounterSample.cs
Source:
CounterSample.cs
Source:
CounterSample.cs
Source:
CounterSample.cs
Source:
CounterSample.cs

Initialise une nouvelle instance de la CounterSample structure et définit la CounterTimeStamp propriété sur la valeur passée.

public:
 CounterSample(long rawValue, long baseValue, long counterFrequency, long systemFrequency, long timeStamp, long timeStamp100nSec, System::Diagnostics::PerformanceCounterType counterType, long counterTimeStamp);
public CounterSample(long rawValue, long baseValue, long counterFrequency, long systemFrequency, long timeStamp, long timeStamp100nSec, System.Diagnostics.PerformanceCounterType counterType, long counterTimeStamp);
new System.Diagnostics.CounterSample : int64 * int64 * int64 * int64 * int64 * int64 * System.Diagnostics.PerformanceCounterType * int64 -> System.Diagnostics.CounterSample
Public Sub New (rawValue As Long, baseValue As Long, counterFrequency As Long, systemFrequency As Long, timeStamp As Long, timeStamp100nSec As Long, counterType As PerformanceCounterType, counterTimeStamp As Long)

Paramètres

rawValue
Int64

Valeur numérique associée à l’exemple de compteur de performances.

baseValue
Int64

Valeur brute de base facultative pour le compteur, à utiliser uniquement si l’exemple est basé sur plusieurs compteurs.

counterFrequency
Int64

Fréquence à laquelle le compteur est lu.

systemFrequency
Int64

Fréquence à laquelle le système lit à partir du compteur.

timeStamp
Int64

Horodatage brut.

timeStamp100nSec
Int64

Horodatage brut et haute fidélité.

counterType
PerformanceCounterType

Objet PerformanceCounterType qui indique le type du compteur pour lequel cet exemple est un instantané.

counterTimeStamp
Int64

Heure à laquelle l’échantillon a été prélevé.

Exemples

L’exemple suivant montre comment initialiser une nouvelle CounterSample structure, en passant des valeurs pour les paramètres et rawValue les baseValueparamètres, counterFrequencysystemFrequencytimeStamptimeStamp100nSeccounterTypecounterTimeStamp Après avoir créé la CounterSample structure, l’exemple affiche les valeurs de propriété de la CounterSample fenêtre de console.

PerformanceCounter myPerformanceCounter1 = new PerformanceCounter
   ("Processor","% Processor Time", "0");
CounterSample myCounterSample1 = new CounterSample(10L, 20L, 30L, 40L, 50L, 60L,
                     PerformanceCounterType.AverageCount64);
Console.WriteLine("CounterTimeStamp = "+myCounterSample1.CounterTimeStamp);

Console.WriteLine("BaseValue = "+myCounterSample1.BaseValue);
Console.WriteLine("RawValue = "+myCounterSample1.RawValue);
Console.WriteLine("CounterFrequency = "+myCounterSample1.CounterFrequency);
Console.WriteLine("SystemFrequency = "+myCounterSample1.SystemFrequency);
Console.WriteLine("TimeStamp = "+myCounterSample1.TimeStamp);
Console.WriteLine("TimeStamp100nSec = "+myCounterSample1.TimeStamp100nSec);
Console.WriteLine("CounterType = "+myCounterSample1.CounterType);
// Hold the results of sample.
myCounterSample1 = myPerformanceCounter1.NextSample();
Console.WriteLine("BaseValue = "+myCounterSample1.BaseValue);
Console.WriteLine("RawValue = "+myCounterSample1.RawValue);
Console.WriteLine("CounterFrequency = "+myCounterSample1.CounterFrequency);
Console.WriteLine("SystemFrequency = "+myCounterSample1.SystemFrequency);
Console.WriteLine("TimeStamp = "+myCounterSample1.TimeStamp);
Console.WriteLine("TimeStamp100nSec = "+myCounterSample1.TimeStamp100nSec);
Console.WriteLine("CounterType = "+myCounterSample1.CounterType);
Dim myPerformanceCounter1 As New PerformanceCounter("Processor", _
                                            "% Processor Time", "0")
Dim myCounterSample1 As New CounterSample(10&, 20&, 30&, 40&, 50&, 60&, _
                               PerformanceCounterType.AverageCount64)
Console.WriteLine("CounterTimeStamp = " & myCounterSample1.CounterTimeStamp)

Console.WriteLine("BaseValue = " & myCounterSample1.BaseValue)
Console.WriteLine("RawValue = " & myCounterSample1.RawValue)
Console.WriteLine("CounterFrequency = " & myCounterSample1.CounterFrequency)
Console.WriteLine("SystemFrequency = " & myCounterSample1.SystemFrequency)
Console.WriteLine("TimeStamp = " & myCounterSample1.TimeStamp)
Console.WriteLine("TimeStamp100nSec = " & myCounterSample1.TimeStamp100nSec)
Console.WriteLine("CounterType = " & myCounterSample1.CounterType.ToString)
' Hold the results of sample.
myCounterSample1 = myPerformanceCounter1.NextSample()

Console.WriteLine("BaseValue = " & myCounterSample1.BaseValue)
Console.WriteLine("RawValue = " & myCounterSample1.RawValue)
Console.WriteLine("CounterFrequency = " & myCounterSample1.CounterFrequency)
Console.WriteLine("SystemFrequency = " & myCounterSample1.SystemFrequency)
Console.WriteLine("TimeStamp = " & myCounterSample1.TimeStamp)
Console.WriteLine("TimeStamp100nSec = " & myCounterSample1.TimeStamp100nSec)
Console.WriteLine("CounterType = " & myCounterSample1.CounterType.ToString)
PerformanceCounter myPerformanceCounter2 = new PerformanceCounter
   ("Processor","% Processor Time", "0");
CounterSample myCounterSample2 = new CounterSample(10L, 20L, 30L, 40L, 50L, 60L,
               PerformanceCounterType.AverageCount64, 300);
Console.WriteLine("CounterTimeStamp = "+myCounterSample2.CounterTimeStamp);
Console.WriteLine("BaseValue = "+myCounterSample2.BaseValue);
Console.WriteLine("RawValue = "+myCounterSample2.RawValue);
Console.WriteLine("CounterFrequency = "+myCounterSample2.CounterFrequency);
Console.WriteLine("SystemFrequency = "+myCounterSample2.SystemFrequency);
Console.WriteLine("TimeStamp = "+myCounterSample2.TimeStamp);
Console.WriteLine("TimeStamp100nSec = "+myCounterSample2.TimeStamp100nSec);
Console.WriteLine("CounterType = "+myCounterSample2.CounterType);
Console.WriteLine("CounterTimeStamp = "+myCounterSample2.CounterTimeStamp);
// Hold the results of sample.
myCounterSample2 = myPerformanceCounter2.NextSample();
Console.WriteLine("BaseValue = "+myCounterSample2.BaseValue);
Console.WriteLine("RawValue = "+myCounterSample2.RawValue);
Console.WriteLine("CounterFrequency = "+myCounterSample2.CounterFrequency);
Console.WriteLine("SystemFrequency = "+myCounterSample2.SystemFrequency);
Console.WriteLine("TimeStamp = "+myCounterSample2.TimeStamp);
Console.WriteLine("TimeStamp100nSec = "+myCounterSample2.TimeStamp100nSec);
Console.WriteLine("CounterType = "+myCounterSample2.CounterType);
Console.WriteLine("CounterTimeStamp = "+myCounterSample2.CounterTimeStamp);
Dim myPerformanceCounter2 As New PerformanceCounter("Processor", _
                                             "% Processor Time", "0")
Dim myCounterSample2 As New CounterSample(10&, 20&, 30&, 40&, 50&, 60&, _
                         PerformanceCounterType.AverageCount64, 300)
Console.WriteLine("CounterTimeStamp = " & myCounterSample2.CounterTimeStamp)
Console.WriteLine("BaseValue = " & myCounterSample2.BaseValue)
Console.WriteLine("RawValue = " & myCounterSample2.RawValue)
Console.WriteLine("CounterFrequency = " & myCounterSample2.CounterFrequency)
Console.WriteLine("SystemFrequency = " & myCounterSample2.SystemFrequency)
Console.WriteLine("TimeStamp = " & myCounterSample2.TimeStamp)
Console.WriteLine("TimeStamp100nSec = " & myCounterSample2.TimeStamp100nSec)
Console.WriteLine("CounterType = " & myCounterSample2.CounterType.ToString)
Console.WriteLine("CounterTimeStamp = " & myCounterSample2.CounterTimeStamp)

' Hold the results of sample.
myCounterSample2 = myPerformanceCounter2.NextSample()
Console.WriteLine("BaseValue = " & myCounterSample2.BaseValue)
Console.WriteLine("RawValue = " & myCounterSample2.RawValue)
Console.WriteLine("CounterFrequency = " & myCounterSample2.CounterFrequency)
Console.WriteLine("SystemFrequency = " & myCounterSample2.SystemFrequency)
Console.WriteLine("TimeStamp = " & myCounterSample2.TimeStamp)
Console.WriteLine("TimeStamp100nSec = " & myCounterSample2.TimeStamp100nSec)
Console.WriteLine("CounterType = " & myCounterSample2.CounterType.ToString)
Console.WriteLine("CounterTimeStamp = " & myCounterSample2.CounterTimeStamp)

Remarques

Utilisez ce constructeur pour prendre des échantillons après avoir déjà pris un échantillon initial du compteur de performances. Le Moniteur système fournit automatiquement des valeurs pour ces paramètres lorsque vous appelez la NextSample méthode.

S’applique à